1.高级别洁净厂房空调系统宜独立设置。所谓高级别洁净厂房是指千级以上洁净厂房,其原因是高级别洁净厂房空调送风量大,如同样面积的洁净厂房,百级洁净厂房的空调风量是十万级的3.4倍,是万级的2.25倍。另外高级别洁净厂房的使用频率远低于低级别手术室,这样无论是一个空调系统负担多个高级别洁净厂房,或是一个空调系统负担一个高级别洁净厂房和多个低级别洁净厂房,都会使空调系统长时间处于"大马拉小车"的运行状态。例如一个空调系统负担1间百级洁净厂房和2间万级手术室或4间十万级洁净厂房,只要高级别洁净厂房不使用,则洁净厂房设计施工系统设计风量至少大于此时所需风量的112%和84%,亦即此时系统所需风量仅为系统设计风量的47%和54.3%,而且此种因洁净厂房使用与否引起的风量变化,不宜采用变频调速方式进行调节,只能用调节总风阀的方式调节风量以适应系统风量变化,然而此种方式显然不节能。所以无论从节约能源的角度,或是从使用可靠性、灵活性的角度,高级别洁净厂房都应"按间"独立设置空调系统,即一个净化空调系统对应一间洁净厂房。
 
1 high level clean room air-conditioning system should be independent set. The so-called high-level clean plant is a thousand or more clean plant, the reason is the high level of air conditioning air supply, as the sample size of the clean room, clean room air conditioning air is 3.4 times one hundred thousand times, is 2.25 times. In addition to the use of high levels of clean plant frequency is far lower than the low level operation room, so whether it is a burden on a large air-conditioning system to clean the plant, or a high level of air conditioning system to burden a high level of clean plant and a number of low-level clean plant, will make the air conditioning system long time in the running state of the big horse car. Such as an air conditioning system burden of 1 hundred grade clean workshop and 2 or one hundred thousand grade clean workshop, as long as the high level of clean plant is not used, the design and construction system design and construction system is at least 112% and 84%, which means the system is designed for the system design of 47% and 54.3%, and this is due to the use of variable frequency speed adjustment, adjustment of the total air valve to adjust the air volume to adapt to the system, but this way is not energy. Therefore, whether from the perspective of energy conservation, or from the use of reliability, flexibility, the high level of clean plant should be "according to the" independent air-conditioning system, that is, a clean air-conditioning system corresponding to a clean plant.
 
2.对于低级别洁净厂房,尽管与高级别洁净厂房相比空调风量小的多,但一个空调系统所负担的洁净厂房间数也不宜过多,因为洁净厂房的使用情况具备不确定性。愈是高等级厂家,洁净厂房为满足特殊繁忙情况,设置愈多。手术室多,正常情况下的同时使用系数低,这样当一个空调系统所负担的洁净厂房间数较多时,系统常处于"供大于求"的状态,其运行能耗势必较高,就象有的厂家所反映的"建的起,用不起"。对于低级别洁净厂房一个空调系统所负担的洁净厂房不宜多于四至五间,而且一个系统负担洁净厂房过多,也会造成使用上的不可靠。
 
2 for the low level of clean plant, despite the high level of clean room air conditioning air is much smaller, but an air conditioning system, the burden of the clean room number also should not be too much, because the use of clean plant with uncertainty. The more high grade manufacturers, clean workshop to meet the special busy, set the. Operation room, normal circumstances, while the use of low coefficient, so that when a large number of air-conditioning system burden of a large number of clean room, the system is often in a state of oversupply, the energy consumption will be higher, as some manufacturers reflect the construction of the up, can not afford". For low level cleanroom air conditioning system of the burden of clean plant should not be more than four to five, and a burden on the system clean workshop too much, caused by the use of unreliable.
 
3.中央清洁大厅、清洁走廊、高级别手术间的准备区、无菌室等应由一个单独的空调系统负担,目的是保证洁净厂房外部空气环境时时处于"临战"状态,那种将以上部位空调合在低级别洁净厂房空调系统中的做法
 
. central clean hall, corridor in the clean and high level operation between the preparation zone, sterile rooms should be a separate air conditioning system burden, the purpose of which is to ensure clean workshop outside air environment are always in the "battle" state, that will be part of the air conditioner in the low-level clean factory building air conditioning system
 
显然不合理。因为合在一起的空调系统,或是在洁净厂房停止使用时系统送风能耗过大,或是无法保证洁净厂房设计施工外部气候环境处于受控状态。
 
Obviously unreasonable. Because of the air conditioning system, or in the clean plant to stop using the system to send wind energy consumption is too large, or can not guarantee the clean plant design and construction of the external climate environment in a controlled state.
 
洁净厂房空调风系统的划分原则应该是运行可靠、调节灵活、各司其责、节约能源。在洁净厂房设计施工 http://www.jnjkjh.com/ 方面,巨康是专业的,行业内领军品牌,值得您的信赖!
 